Marine Explosion-Proof Fans With Water Driven
1. Fan General
CSZ, CSL water-driven explosion-proof axial fan with water driven have anti-high hazard classification, sound anti-wooble, anti-vibration and anti-impact performance. The fan of single stage, low weight, small size, simplicity of operation and it was in a post- stability / normally only one operator of required. Driven directly by fire protection water, this ventilator depends on no other power. With sealed bearings, it gives good service at temperatures. Blast safety of this type is also called a water turbine (or water turbine impeller motor) to overheat with water.
2. Structure
CSZ series ventilator fan is composed of water turbine, frame, casing, rotor and impeller. The water turbine is precisely cast of anti-corrosion copper alloy, the casing is soldered of austenitic stainless steel. The impeller is made of high strength aluminum alloy with the whole structure of no-spark design. The angle for air are 18° for air supply and 22° for air return. A kind of nozzle for discharge in a possible direction.
CSL ventilator fan is composed of water turbine, frame, casing and air compressor. The water turbine is precisely cast of anti-corrosion copper alloy, the casing is soldered of austenitic stainless steel and the impeller is cast of high strength aluminum alloy with the whole structure of no-spark design. The angle for air are 18° for air supply and 22° for air return. A kind of this type of ventilator can’t change the model.
3. Fan applicable conditions
For places where there are explosive grade IIB and IIC and group from T4 to T6, the air temperature is from -25°C~+55°C; relative humidity of the air: ≤ 95%; cyclical ventilation: 22~9 (24~26) etc.; air pressure: ±10Kpa; saturated air humidity: 100%; vibration: 10mm; shock: existence.
4. Model explanation
(Diagrammatic layout)
-
C – Marine or navy
-
S – Water driven
-
Z – Explosion-proof axial fan (L for explosion-proof centrifugal fan)
-
– 300 – Impeller diameter is 300mm (260mm for L series, casing diameter 380mm)
CSZ Main Property Parameters and Outline Dimensions
| Type | Flow rate m³/h | Static pressure Pa | Inlet water pressure MPa | Water consumption m³/h | D1 | D2 | D3 | D4 | H | n-d | Weight kg |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CSZ-300 | 3000~4000 | 260~820 | 0.2~0.7 | 25~43 | Φ300 | Φ336 | Φ360 | Φ446 | 404 | 8-Φ11 | 28 |
| CSZ-380 | 4000~10000 | 380~1020 | 0.2~0.7 | 28~53 | Φ380 | Φ416 | Φ446 | Φ546 | 404 | 8-Φ11 | 33 |
Note: Characteristic curves for CSZ-300 and CSZ-380 are provided in the original image, showing the relationship between Air Volume, Static Pressure, Water Pressure, and Water Consumption.
CSL Main Property Parameters and Outline Dimensions
| Type | Flow rate m³/h | Static pressure Pa | Inlet water pressure MPa | Water consumption m³/h | D1 | D2 | D3 | L | B | H | n-d | Weight kg |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CSL-240 | 2000~5000 | 920~1700 | 0.2~0.7 | 34~56 | Φ270 | Φ290 | Φ380 | 585 | 470 | 455 | 6-Φ10 | 55 |
| CSL-260 | 3000~6000 | 1000~1500 | 0.2~0.7 | 34~56 | Φ270 | Φ290 | Φ380 | 640 | 470 | 490 | 6-Φ10 | 60 |
Note: Characteristic curves for CSL-240 and CSL-260 are provided in the original image, showing the relationship between Air Volume, Static Pressure, Water Pressure, and Water Consumption.
Note: The description may be different with the product, please contact us for quotation.
Click here to contact us via whatsapp for details
Tag: Our other products