1. Fan General

CSZ, CSL water-driven explosion-proof axial fan with water driven have anti-high hazard classification, sound anti-wooble, anti-vibration and anti-impact performance. The fan of single stage, low weight, small size, simplicity of operation and it was in a post- stability / normally only one operator of required. Driven directly by fire protection water, this ventilator depends on no other power. With sealed bearings, it gives good service at temperatures. Blast safety of this type is also called a water turbine (or water turbine impeller motor) to overheat with water.

2. Structure

CSZ series ventilator fan is composed of water turbine, frame, casing, rotor and impeller. The water turbine is precisely cast of anti-corrosion copper alloy, the casing is soldered of austenitic stainless steel. The impeller is made of high strength aluminum alloy with the whole structure of no-spark design. The angle for air are 18° for air supply and 22° for air return. A kind of nozzle for discharge in a possible direction.
CSL ventilator fan is composed of water turbine, frame, casing and air compressor. The water turbine is precisely cast of anti-corrosion copper alloy, the casing is soldered of austenitic stainless steel and the impeller is cast of high strength aluminum alloy with the whole structure of no-spark design. The angle for air are 18° for air supply and 22° for air return. A kind of this type of ventilator can’t change the model.

3. Fan applicable conditions

For places where there are explosive grade IIB and IIC and group from T4 to T6, the air temperature is from -25°C~+55°C; relative humidity of the air: ≤ 95%; cyclical ventilation: 22~9 (24~26) etc.; air pressure: ±10Kpa; saturated air humidity: 100%; vibration: 10mm; shock: existence.

4. Model explanation

(Diagrammatic layout)

  • C – Marine or navy

  • S – Water driven

  • Z – Explosion-proof axial fan (L for explosion-proof centrifugal fan)

  • – 300 – Impeller diameter is 300mm (260mm for L series, casing diameter 380mm)


CSZ Main Property Parameters and Outline Dimensions
Type Flow rate m³/h Static pressure Pa Inlet water pressure MPa Water consumption m³/h D1 D2 D3 D4 H n-d Weight kg
CSZ-300 3000~4000 260~820 0.2~0.7 25~43 Φ300 Φ336 Φ360 Φ446 404 8-Φ11 28
CSZ-380 4000~10000 380~1020 0.2~0.7 28~53 Φ380 Φ416 Φ446 Φ546 404 8-Φ11 33

Note: Characteristic curves for CSZ-300 and CSZ-380 are provided in the original image, showing the relationship between Air Volume, Static Pressure, Water Pressure, and Water Consumption.


CSL Main Property Parameters and Outline Dimensions
Type Flow rate m³/h Static pressure Pa Inlet water pressure MPa Water consumption m³/h D1 D2 D3 L B H n-d Weight kg
CSL-240 2000~5000 920~1700 0.2~0.7 34~56 Φ270 Φ290 Φ380 585 470 455 6-Φ10 55
CSL-260 3000~6000 1000~1500 0.2~0.7 34~56 Φ270 Φ290 Φ380 640 470 490 6-Φ10 60

Note: Characteristic curves for CSL-240 and CSL-260 are provided in the original image, showing the relationship between Air Volume, Static Pressure, Water Pressure, and Water Consumption.