Insulation shipboard power cable

Place of Origin: Made In China
Specification: Please contact us for details.

Click here to send inquiry via whatsapp

Category:

Insulation shipboard power cable

1. CEFP/DA, SACEHP/DA, SACEVP/DA, SACEFRP/DA, SACEPJP/SC, CEPFP/SC

  • Cross – sectional View:
      1. Tinned copper conductor
      1. EPR insulated
      1. Tinned copper wire individual screen
      1. Tape
      1. Chlorinated polyethylene/chlorosulfonated polyethylene/polyvinyl chloride/cross – linked polyethylene sheath (PCP/CSP/PVC/Cross – linked PO/PO sheath)

2. CEFP80/DA, SACEHP80/DA, SACEVP80/DA, SACEPJP80/SC, CEPFP80/SC, CEFP90/DA, SACEHP90/DA, SACEVP90/DA, SACEPJP90/SC, CEPFP90/SC

  • Cross – sectional View:
      1. Tinned copper conductor
      1. EPR insulated
      1. Tinned copper wire individual screen
      1. Tape
      1. Chlorinated polyethylene/chlorosulfonated polyethylene/polyvinyl chloride/cross – linked polyethylene inner sheath (PCP/CSP/PVC/Cross – linked PO/PO inner sheath)
      1. Tinned copper wire/galvanized steel wire braided armoured

3. CEFP82/DA, SACEHP82/DA, SACEVP82/DA, SACEPJP85/SC, CEPFP86/SC, CEFP92/DA, SACEHP92/DA, SACEVP92/DA, SACEPJP95/SC, CEPFP96/SC

  • Cross – sectional View:
      1. Tinned copper conductor
      1. EPR insulated
      1. Tinned copper wire individual screen
      1. Tape
      1. Chlorinated polyethylene/chlorosulfonated polyethylene/polyvinyl chloride/cross – linked polyethylene inner sheath (PCP/CSP/PVC/Cross – linked PO/PO inner sheath)
      1. Tinned copper wire/galvanized steel wire braided armoured
      1. Chlorinated polyethylene/chlorosulfonated polyethylene/polyvinyl chloride/cross – linked polyethylene outer sheath (PCP/CSP/PVC/Cross – linked PO/PO outer sheath)

Note: The conductors of fill are decided by technics requirement.

Technical Data Tables

Table 1: For CEFP/DA, SA, CEFP80/DA, SA, CEFP90/DA, SA, CEFP82/DA, SA, CEFP92/DA, SA (90°C)

Core×label Calculated diameter (mm) Calculated mass (kg/km) Calculated diameter (mm) Calculated mass (kg/km) Calculated diameter (mm) Calculated mass (kg/km)
nom max nom max nom max
1×1 6.1 7.1 80 7.7 8.7 155
1×1.5 6.8 7.8 108 8.4 9.4 190
… (all rows as in original table 11)…
3×185 55.5 57.5 8412 58.7 60.7 10042

Table 2: For CEFP/DA, SA, CEFP80/DA, SA, CEFP90/DA, SA, CEFP82/DA, SA, CEFP92/DA, SA (another set of data in original table 12)

Core×label Calculated diameter (mm) Calculated mass (kg/km) Calculated diameter (mm) Calculated mass (kg/km) Calculated diameter (mm) Calculated mass (kg/km)
nom max nom max nom max
4×1.5 12.1 13.1 272 13.3 14.3 391
4×2.5 14.1 15.1 387 15.3 16.3 500
… (all rows as in original table 12)…
37×2.5 57.8 59.8 2193 60.1 62.1 2560

The above parameters are for reference only, and the actual values shall prevail.