LC Oval gear Flowmeter
Product Introduction
Lc series oval gear flowmeter is the main products of our company. Lc oval gear flowmeter is one of the typical displacement meter, used for measurement of pipeline fluid flow under certain pressure. It has a simple structure, reliable use and high accuracy, flow field has no special requirements for import and export of the pipe, the viscosity of the measured medium range and the characteristics of the flow range is very wide. And therefore is widely used in petroleum, chemical industry, medicine, transportation, food and other industrial and commercial sector of liquid flow detection. Lc series oval gear flowmeter is particularly suited to the measurement of oil fuel.
In order to meet market and customer demands, combined with 10 years manufacturing experience, continuous improvement and innovation, introduced in different environmental conditions are suitable for the use of elliptical gear flowmeter products. Far eastone oval gear flowmeter, light-weight oval gear flowmeter, high-temperature type oval gear flowmeter and etc.
Product standards and production license
-
The professional standards of the People’s Republic of China JB/T9242-1999(General technical conditions the liquid volume flowmeter)
-
Enterprise standard <Liquid volume flowmeter> (Q/02J004-2010)
-
Connecting flange standards: JB/T79-82-1994, GB/T9112-2000
-
Protection grades: transmitter IP65, Speeder, counter IP56.
Product Usage
-
LC-A type cast iron oval gear flowmeter, widely used in all kinds of oil products and for the measurement of the cast iron material not corrosion liquid medium.
-
LC-E type stainless steel oval gear flowmeter. Used for high pressure, low corrosive medium measurement.
-
LC-C type cast iron oval gear flowmeter. The rotor for aluminum alloy, is suitable for low viscosity, low corrosion, such as gasoline, etc. the measurement of liquid medium.
-
LC-H: C type stainless steel oval gear flowmeter. Widely used in strong corrosive liquid medium, such as acid, alkali, salt and organic compounds, the measurement of liquid medium.
-
LC-L1: type aluminum alloy oval gear flowmeter, is a small oval gear flowmeter, widely used in low corrosive liquid medium, such as water, such as the measurement of liquid medium.
Oval gear flowmeter technical parameters
-
The more common material and the nominal pressure
| Meter body | rotor | Cover board | Oval gear | axle sleeve | nominal diameter (MPa) |
| :— | :— | :— | :— | :— | :— |
| LC-A | cast iron | cast iron | cast iron | aluminum alloy | cast iron | 1.6 |
| LC-E | cast iron | cast iron | stainless steel | carbon steel | 10/1.6, DN80~DN150 : 2.5MPa |
| LC-C | cast iron | cast iron | cast iron | aluminum alloy | graphite | 1.6 |
| LC-H | stainless steel | stainless steel | stainless steel | stainless steel | graphite or | shown above |
| | | | | | teflon | |
Note: LC-E volume 10 (metric) type, LC-E structure as shown, DN80 or so, 2.5MPa, LC-E, (4MPa) pressure flange connection type. When The meter works on pressure can be 2.5MPa, 4MPa. Flange can be made specially, 4 MPa. Flange has the two kinds: GB and JB.
-
Accuracy class: 0.5grade, 0.2grade
-
working temperature: LC-A, LC-CQ series(-20℃~+60℃); LC-B、E、L series(-41℃~+60℃)
Under the high temperature adjustment, and high temperature heat tube can reach 60 ℃ to 200 ℃; -
Far eastone explosion-proof grade display screen: Exia IICT5; dII BT5
-
Flow range as shown in the table below (unit: m³/h)
| Model | Nominal diameter (mm) | 0.3-0.6 | 0.6-2 | 2-200 | 200-1000 | 1000-2000 | standard counter |
| :— | :— | :— | :— | :— | :— | :— | :— |
| LC-10 | 10 | 0.2*0.5 | 0.15*0.5 | 0.1*0.5 | 0.1*0.5 | 0.05*0.5 | 0.03*0.3 | 0.03*0.3 | 0.03*0.2 | |
| LC-15 | 15 | 0.75*1.5 | 0.5*1.5 | 0.3*1.5 | 0.3*1.5 | 0.15*1.5 | 0.2*1.0 | 0.1*1.0 | 0.07*0.7 | |
| LC-20 | 20 | 1.5*3 | 1*3 | 0.5*3 | 0.5*3 | 0.3*3 | 0.4*2.1 | 0.2*2.1 | 0.15*1.5 | IV/A1 |
| LC-25 | 25 | 3*6 | 2*6 | 1*6 | 1*6 | 0.6*6 | 0.8*4.2 | 0.4*4.2 | 0.3*3 | |
| LC-40 | 40 | 7.5*15 | 5*15 | 2.5*15 | 2.5*15 | 1.5*15 | 2.1*10.5 | 1.0*10.5 | 0.7*7.5 | |
| LC-50 | 50 | 8*24 | 8*24 | 4.8*24 | 4.8*24 | 2.4*24 | 2.4*16.8 | 1.6*16.8 | 1.2*12 | |
| LC-B40/50 | 40/50 | 6*20 | 5*20 | 4*20 | 1*20 | 2*20 | 2*14 | 1.4*14 | 1.0*10 | |
| LC-65 | 65 | 20*40 | 15*40 | 8*40 | 8*40 | 4*40 | 5.6*28 | 2.8*28 | 2*20 | |
| LC-80 | 80 | 30*60 | 20*60 | 12*60 | 12*60 | 6*60 | 8.4*42 | 4.2*42 | 3*30 | IV/II/A5 |
| LC-100 | 100 | 50*100 | 34*100 | 20*100 | 20*100 | 10*100 | 14*70 | 7*70 | 5*50 | |
| LC-150 | 150 | 95*190 | 54*190 | 38*190 | 38*190 | 19*190 | 26.6*133 | 13.3*133 | 9.5*95 | |
| LC-200 | 200 | 170*340 | 114*340 | 56*340 | 56*340 | 34*340 | 47.6*238 | 23.8*238 | 17*170 | |
| Accuracy class | | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.5 | 0.2 | 0.5 | |
Note: When the measured liquid viscosity is more than 2000 mpa.s, flowmeter adopts viscous structure, can be used for 2000 mpa.s or higher, flow range or parameter negotiable.
LC-series other special oval gear flowmeters
-
Far eastone oval gear flowmeter overview
Far eastone oval gear flowmeter is composed of ontology and the transmitter, liquid in the pipe flow can be directly converted into flow pulse signal or analog signal output. The flow pulse signal or analog signals and our factory EL series display instrument or other secondary instrument and supporting system, which can realize remote measurement display, Automatic control, record the need of adjustment. -
Technical index
-
The level of accuracy: 0.5, 0.2
-
Working temperature: general work in -20~+60 (℃)
-
The transmitter type: QF, GF, MF, Ag19
-
The transmitter structure: BGF, EX, LC-13
-
Light-weight Oval gear flowmeter
-
Light-weight oval gear flowmeter is mainly in order to reduce flowmeter convenient customer use and research and development, features: the volume is small, light in weight, and it is mainly used for the measurement of pressure liquid.
(LC-XX: A series) and whole aluminum alloy meter (LC- L, LC- AL series) This flowmeter is light-weight design, light weight, unique and beautiful appearance, convenient operation, high accuracy, large, medium and small flow linear accuracy, repeatability is good. Wait for the character site.
-
Technical index
(1) The level of accuracy 0.5, 0.2
(2) The nominal pressure 1.6 MPa
(3) The technical parameters see LC series
(4) Main component materials in the following table
| Model | Meter body | cover board | oval gear | axle | sleeve |
| :— | :— | :— | :— | :— | :— |
| LC-L | aluminum alloy | cast iron | stainless steel | aluminum alloy | graphite |
| | | | | | Oil bearings, graphite |
| LC-A5 | cast iron | cast iron | cast iron | aluminum alloy | cast iron | -
LC-L series heat preservation jacket oval gear flowmeter
To facilitate easy to solidify or freeze, or under a certain temperature condition, often cooled crystals media reaction in the pipe temperature and temperature monitoring, need to heating system of the pipeline medium, medium heat and heat preservation. Because the oval gear flowmeter installation place is not allowed to pass the steam (steam) to prevent damage meter, therefore we design oval gear flowmeter with insulation jacket products, which outside the meter shell increase insulation jacket, make heat solidified medium melt flow meter, and maintain a certain temperature, so as to ensure the normal operation of flowmeter. Oval gear flow meter installed in front of the filter can also adopt the structure of insulation jacket.
Heat preservation jacket in and out of the structure, generally according to DN15 flange design, special requirements can also design the user interface. Heat preservation jacket nominal pressure 0.5 MPa, can also be adjusted according to customer special requirements. -
LC-Dseries mechanical quantitative oval gear flowmeter
LC – D type quantitative mechanical oval gear flowmeter (hereafter referred to as the flowmeter) is a special flow meter, it is composed of oval gear flow meter, reducer and quantitative counter of three parts, can accurately measure the cumulative amount of the liquid, when the number to the expected value, shut automatically turn on the electric circuit control valve, thus satisfies the requirement of flow metering control. Volumetric flowmeter series parts and structure form selection reference -
Counter and governor
| | counter | Performance parameters | Regular configuration |
| :— | :— | :— | :— |
| A | A1 | Pointer indicating, 4-bit-wheel accumulation, unit (L) | Pointer indicating, DN50 flowmeter 11.1*2 h, below DN25 11.19*16, DN40 DN100 100*4 h |
| A1 | same as above, configurable to transmitter | | |
| A6 | Pointer indicating, 5-digit wheel accumulator, unit (L), counter assembly, can connect to transmitter | Pointer indicating, DN20 4-2*5-1*2-32.6*6.2, DN15 6.7*2-0.97 h, DN15 6.7*2-0.97 h |
| A | 6-digit accumulator indicator for the cumulative, configurable transmitter | Pointer indicating, DN10 4.5*7.2-2*0.6-6.5*2.5-1.1.2.7 h |
| A9 | Double counter, indicator, 6-digit instructions for total, four accumulator instructions for instantaneous, single class, Come back to zero | Pointer indicating, DN50 flowmeter 1*56.5*2, DN80 50*1.1*10 h, DN100 11.7*11 h, PN1.6 and below, DN20 3000 h |
| Z | Same as above, configurable to transmitter | Pointer indicating, DN100 11.7*10 h, 20-25 m/h, ± 0.5 h |
| M11 | Double counter, instructions; Seven small meter counters for cumulative, Four big tally accumulator for instructions for a single class, come back to zero | Intimately, just configure flowmeters above DN80, DN150, DN200 (1) 1*1.18 h, meet to measure units 100*1.0 h, 200*5 h |
| M12 | Same as above, Only the difference between on analogy output shaft outlet and counter display screen 90° rotation | Pointer indicating, DN50 100*0.7 h, meet to measure units 100*1.0 h |
| S1 | Mechanical transient flow indicator display | It’s a transient flow valve display |
| D | Direct-reading electronic display, Can display, single total amount, the instantaneous flow and single reset | Used in flow meter |
| D1 | At the scene of the flame proof counter, display, instantaneous flow, total output pulse analog | Used the volumetric flowmeter |
| D2 | At the scene of the flame proof counter, display, instantaneous flow, total output 4~20mA analog | Used the volumetric flowmeter |
| D3 | At the scene of the flame proof counter, display, instantaneous flow, total output 4-20 analog | Used the volumetric flowmeter |
-
governor: FT1, GTB, Y1, Y2, G
-
Volumetric flowmeter configuration is as follows
| configuration | High total reference size | Function |
| :— | :— | :— |
| A no speeder | 78 | Installed by flowmeters below DN40, Needle roller according to cumulative flow meter, |
| A1 no speeder | 105 | Just used for flowmeters below DN40, Needle roller according to cumulative flow meter, GF, MF transmitter, |
| Z no speeder | 74 (20, 25) | Used for various types of flowmeter, the double function wheel wheel back to zero, long word wheel cumulative flow, Pointer and small wheel can be back to zero, DN40 diameter 74.5 mm (below, less than 62.5 mm), |
| H+FT1 | 129 | Used for LC type flowmeter, Pointer, Needle roller according to cumulative flow, configurable GF, MF transmitter, |
| A5+Y1 | 54+56 | Used for LC type flowmeter, Pointer, accumulator instruction of according to traffic, Can match GF, MF transmitter, |
| A5+Y2 | 54+85.5 | Configure, LC Type Flowmeter, Pointer, accumulative instruction, used for LC type flowmeter, double word wheel back to zero, long word wheel cumulative flow, Pointer and small wheel can be back to zero, configurable GF, MF transmitter, |
| A6+Y1 | 54+56 | Used for LC type flowmeter, pointer, accumulative instruction, the total round, double wheel wheel reset, configurable GF, MF transmitter, |
| A6+Y2 | 54+85.5 | Used for LC type flowmeter, pointer, accumulative instruction, the total round, double wheel wheel reset, Pointer and small wheel can be back to zero, configurable GF, MF transmitter, |
| A5+G | 54+106 | Used for LC type flowmeter, Needle roller according to the cumulative flow, can match GF, MF, |
| A5+GTB | 54+67.5 | Used for LC type flowmeter, Needle roller according to the cumulative flow, can match HGF, IMF |
| A6+G | 54+106 | Used for LC type flowmeter, Needle roller according to the cumulative flow, can match GF, MF |
| A6+GTB | 54+67.5 | Used for LC type flowmeter, Needle roller according to the cumulative flow, can match HGF, IMF, |
| M11+GTB | 350+67.5 | Used for LC type flowmeter, Double word wheel back to zero flow, long word wheel cumulative flow, Pointer and small wheel can be back to zero, configurable HGF, MF, |
| M12+GTB | 350+67.5 | Used for LC type flowmeter, Double word wheel back to zero flow, long word wheel cumulative flow, Pointer and small wheel can be back to zero, display, counter display screen ° 90° rotation, Needle roller according to the traffic, can match HGF, MF, |
| D1/D2/D3 | 55, 56.2 | Far eastone LC – LC – D type meter (1) metrology indicates manual meter display |
| | 65, 145 | See the product introduction |
Four, radiator is just used for high temperature, as the below shown
DN15 40 High- temperature radiator
DN50/200 High- temperature radiator
Note: In the model T for heat flow meter, for 60-120 ℃, configuration with third temperature, configuration short radiator. Model is T1 for heat flow meter, for 120-180℃ configuration with radiator. Model T2 for heat flow meter, for 60-120℃ temperature, configuration short radiator.
Product structure form
Note: ① transmitter ②Speeder ③counter ④sender unit ⑤radiator
Oval gear flowmeters product mark
| Type code | Note | |
|---|---|---|
| LC | Oval gear flowmeter | |
| U | With isolation jacket structure | |
| T | Pipe thermal connection | |
| H | Welded steel flow meter | |
| P | Nuclear power products | |
| D | Mechanical quantitative flow meter | |
| N | High viscosity liquid flow meter | |
| SP | Food flowmeter | |
| T1, T2 | Thermal insulation cooling tube | |
| D | Micro quantitative flow meter | |
| Material symbol shell | A | cast iron flowmeter |
| B | stainless steel flowmeter | |
| E | cast steel flowmeter | |
| Nominal diameter | 10 ~ 300, 200 | nominal diameter (from 10mm, … … to 200mm) |
| Nominal pressure | 1.5 (K) | Flange connection (Class) |
| 2 | Improved type | |
| 4 | nominal pressure 1.6MPa | |
| 7 | nominal pressure 2.5MPa | |
| nominal pressure 4MPa | ||
| A, A1 | used for flowmeter below DN40 | |
| A5, A6 | used for flowmeter above DN50 | |
| D1/D2/D3 | Type electronic digital display counter | |
| Z, S | Pointer counter | |
| sender unit | GF-1 | Standard LC-III type flowmeter |
| GF-2 | 1,2V three wire system photoelectric transmitter | |
| HF-1 | 2,4V three wire system photoelectric transmitter | |
| MF | 2,4V Analog and output transmitter | |
| AG19 | High precision flowmeter |
Note: Oval gear material and seal material when specify, the elliptical gear material can not note, 1 material: HBG, HBGII, 1. Cr18Ni9Ti, Cr18Ni12Mo2Ti
-
Before the transmitter H, and explosion-proof transmitter,
-
High temperature, etc. Q, HF, need to use special cooling tube, (not note cooling tube), such as LC-HIIQ, H2B, etc.
-
Our company adopts anti-corrosion of the gas in the gas in the gas, LC (L) to transplant product model identification, old customers still continue to use, To identify, suggest new customers use new logo.
such as: LC-T1ET1, G-B, G-II-H2, etc.: High temperature type oval gear flowmeter without the cooling tube, Cast steel material, nominal pressure 2.5MPa, under high temperature, etc. And add “STL”, 24V Photoelectric pulse transmitter.
Special version
M1 BG SH SM AS JS
military navy field engineering | Water conservancy engineering | nuclear power engineering | Water supply | drainage | Manually operated Hand wheel
Note: The description may be different with the product, please contact us for quotation.
Click here to contact us via whatsapp for details
Tag: Our other products