Insulation flame retardant ship power cable
1. CEF/DA, SACEH/DA, SACEV/DA, SACEPJ/SC, CEPF/SC, CEFR/DA, SACEHR/DA, SACEVR/DA, SACEPJR/SC, CEPFR/SC
- Cross-sectional View:
-
- Tinned copper conductor
-
- EPR insulated
-
- Tape
-
- Chlorinated polyethylene/polyethylene/polyvinyl chloride/cross-linked polyethylene/polyolefin sheath (PCP/CSP/PVC/Cross-linked PO/PO sheath)
-
2. CEF80/DA, SACEH80/DA, SACEV80/DA, SACEPJ80/SC, CEPF80/SC, CEF90/DA, SACEH90/DA, SACEV90/DA, SACEPJ90/SC, CEPF90/SC
- Cross-sectional View:
-
- Tinned copper conductor
-
- EPR insulated
-
- Tape
-
- Chlorinated polyethylene/polyethylene/polyvinyl chloride/cross-linked polyethylene/polyolefin sheath (PCP/CSP/PVC/Cross-linked PO/PO sheath)
-
- Tinned copper wire/galvanized steel wire braided armoured
-
3. CEF82/DA, SACEH82/DA, SACEV82/DA, SACEF8/DA, SACEH8H/DA, SA, CEF92/DA, SACEH92/DA, SACEV92/DA, SACEPJ95/SC, CEPF95/SC, CEPJ96/SC, CEPF96/SC
- Cross-sectional View:
-
- Tinned copper conductor
-
- EPR insulated
-
- Tape
-
- Chlorinated polyethylene/polyethylene/polyvinyl chloride/cross-linked polyethylene/polyolefin inner sheath (PCP/CSP/PVC/Cross-linked PO/PO sheath)
-
- Tinned copper wire/galvanized steel wire braided armoured
-
- Chlorinated polyethylene/polyethylene/polyolefin outer sheath (PCP/CSP/Cross-linked PO/PO sheath)
-
Note: The conductors of fill are decided by technics requirement.
Technical Data Tables
Table 1: For CEF/DA, SACEH/DA, SACEV/DA, etc. (90°C)
| Core×label | Calculated diameter (mm) | Calculated mass (kg/km) | Calculated diameter (mm) | Calculated mass (kg/km) |
|---|---|---|---|---|
| nom | max | nom | max | |
| 1×1.5 | 5.4 | 6.7 | 60 | 7.0 |
| 1×2.5 | 6.1 | 7.5 | 75 | 7.3 |
| … (all rows as in original table)… | ||||
| 3×185 | 53.4 | 55.4 | 7656 | 54.6 |
Table 2: For CEF80/DA, SACEH80/DA, etc. (90°C)
| Core×label | Calculated diameter (mm) | Calculated mass (kg/km) | Calculated diameter (mm) | Calculated mass (kg/km) |
|---|---|---|---|---|
| nom | max | nom | max | |
| 1×1.5 | 5.6 | 6.4 | 63 | 7.0 |
| 1×2.5 | 6.4 | 7.4 | 79 | 7.8 |
| … (all rows as in original table)… | ||||
| 3×185 | 54.8 | 56.6 | 8349 | 56.0 |
Table 3: For CEF82/DA, SACEH82/DA, etc. (90°C)
| Core×label | Calculated diameter (mm) | Calculated mass (kg/km) | Calculated diameter (mm) | Calculated mass (kg/km) |
|---|---|---|---|---|
| nom | max | nom | max | |
| 1×1.5 | 10.3 | 11.3 | 159 | 11.7 |
| 1×2.5 | 10.9 | 11.9 | 188 | 12.3 |
| … (all rows as in original table)… | ||||
| 3×185 | 55.4 | 57.4 | 9166 | 57.6 |
The above parameters are for reference only, and the actual values shall prevail.
Attention please: The description may be different with the product, please contact us for quotation.