XLPE Insulation Shipboard Fire Resting Symmetrical Communication Cable
Model Specifications
CHJ85/NC, CHJ86/NC; CHJ85/NC CHJ86/NC (Aluminum – polyester tape collective screen); CHJ85/NC CHJ86/NC (Aluminum – plastic composite foil individual and collective screen)
Cable Structure Diagram and Component Description
First Structure (CHJ85/NC, CHJ86/NC)
- Tinned copper conductor
- Layer for fire – proof
- XLPE insulated
- Tape
- Tinned copper wire individual screen
- Cross – linked PO/PO outer sheath
Second Structure (CHJ85/NC CHJ86/NC with Aluminum – polyester tape collective screen)
- Tinned copper conductor
- Layer for fire – proof
- XLPE insulated
- Tinned copper drain wire
- Aluminum – backed polyester tape collective screen
- Tape
- Tinned copper wire braid
- Cross – linked PO/PO outer sheath
Third Structure (CHJ85/NC CHJ86/NC with Aluminum – plastic composite foil individual and collective screen)
- Tinned copper conductor
- Layer for fire – proof
- XLPE insulated
- Aluminum – plastic composite foil individual and collective screen
- Tinned copper drain wire
- Tape
- Tinned copper wire braid
- Cross – linked PO/PO outer sheath
Note: The conductions of fill are decided by technics requirement.
Technical Parameters Table (150/250V, 90°C)
For models: CHJ85/NC, CHJ86/NC
| Number of Cores × Nominal Cross – Sectional Area (mm²) | Calculated Diameter (mm) | Calculated Mass (kg/km) | |
|---|---|---|---|
| Nominal Value | Maximum Value | ||
| 1×2×0.75 | 7.4 | 8.4 | 79 |
| 2×2×0.75 | 10.5 | 11.5 | 152 |
| 3×2×0.75 | 11.5 | 12.5 | 192 |
| … (continue with all rows as per original table for this part) |
For models: CHJ85/NC CHJ86/NC (Al/polyester tape collective screen)
| Number of Cores × Nominal Cross – Sectional Area (mm²) | Calculated Diameter (mm) | Calculated Mass (kg/km) | |
|---|---|---|---|
| Nominal Value | Maximum Value | ||
| 1×2×0.75 | 7.6 | 8.6 | 87 |
| 2×2×0.75 | 11.2 | 12.2 | 174 |
| 3×2×0.75 | 11.8 | 12.8 | 203 |
| … (continue with all rows as per original table for this part) |
For models: CHJ85/NC CHJ86/NC (Al/plastic composite foil individual and collective screen)
| Number of Cores × Nominal Cross – Sectional Area (mm²) | Calculated Diameter (mm) | Calculated Mass (kg/km) | |
|---|---|---|---|
| Nominal Value | Maximum Value | ||
| 1×2×1.5 | 8.9 | 9.9 | 113 |
| 2×2×1.5 | 13.0 | 14.0 | 230 |
| 3×2×1.5 | 14.0 | 15.0 | 285 |
| … (continue with all rows as per original table for this part) |
Note: The above parameters are for reference only. If technical confirmation is required, please refer to the actual technical requirements.
Attention please: The description may be different with the product, please contact us for quotation.