Insulation Shipboard Fire Resting Communication Cable

Place of Origin: Made In China
Specification: Please contact us for details.

Click here to send inquiry via whatsapp

Category:

XLPE Insulation Shipboard Fire Resting Symmetrical Communication Cable

Model Specifications

CHJ85/NC, CHJ86/NC; CHJ85/NC CHJ86/NC (Aluminum – polyester tape collective screen); CHJ85/NC CHJ86/NC (Aluminum – plastic composite foil individual and collective screen)

Cable Structure Diagram and Component Description

First Structure (CHJ85/NC, CHJ86/NC)

  1. Tinned copper conductor
  2. Layer for fire – proof
  3. XLPE insulated
  4. Tape
  5. Tinned copper wire individual screen
  6. Cross – linked PO/PO outer sheath

Second Structure (CHJ85/NC CHJ86/NC with Aluminum – polyester tape collective screen)

  1. Tinned copper conductor
  2. Layer for fire – proof
  3. XLPE insulated
  4. Tinned copper drain wire
  5. Aluminum – backed polyester tape collective screen
  6. Tape
  7. Tinned copper wire braid
  8. Cross – linked PO/PO outer sheath

Third Structure (CHJ85/NC CHJ86/NC with Aluminum – plastic composite foil individual and collective screen)

  1. Tinned copper conductor
  2. Layer for fire – proof
  3. XLPE insulated
  4. Aluminum – plastic composite foil individual and collective screen
  5. Tinned copper drain wire
  6. Tape
  7. Tinned copper wire braid
  8. Cross – linked PO/PO outer sheath

Note: The conductions of fill are decided by technics requirement.

Technical Parameters Table (150/250V, 90°C)

For models: CHJ85/NC, CHJ86/NC

Number of Cores × Nominal Cross – Sectional Area (mm²) Calculated Diameter (mm) Calculated Mass (kg/km)
Nominal Value Maximum Value
1×2×0.75 7.4 8.4 79
2×2×0.75 10.5 11.5 152
3×2×0.75 11.5 12.5 192
… (continue with all rows as per original table for this part)

For models: CHJ85/NC CHJ86/NC (Al/polyester tape collective screen)

Number of Cores × Nominal Cross – Sectional Area (mm²) Calculated Diameter (mm) Calculated Mass (kg/km)
Nominal Value Maximum Value
1×2×0.75 7.6 8.6 87
2×2×0.75 11.2 12.2 174
3×2×0.75 11.8 12.8 203
… (continue with all rows as per original table for this part)

For models: CHJ85/NC CHJ86/NC (Al/plastic composite foil individual and collective screen)

Number of Cores × Nominal Cross – Sectional Area (mm²) Calculated Diameter (mm) Calculated Mass (kg/km)
Nominal Value Maximum Value
1×2×1.5 8.9 9.9 113
2×2×1.5 13.0 14.0 230
3×2×1.5 14.0 15.0 285
… (continue with all rows as per original table for this part)

Note: The above parameters are for reference only. If technical confirmation is required, please refer to the actual technical requirements.