Prefabricated Cabin Shore Power Variable Frequency Power Supply
1. Overview
The JDFSP series prefabricated cabin shore power frequency converter utilizes mature high – capacity high – voltage or low – voltage frequency converters as the research and development design platform. The program has been specially optimized for power supply, featuring mature technology, reliable quality, and good stability. It covers multiple voltage levels such as 0.38kV, 6kV, and 10kV in the port power grid, fully adapting to different power supply system requirements of customers. It is widely used in ships, ship manufacturing and repair plants, offshore drilling platforms, shore terminals, and other fields that require 50Hz industrial electricity to be transformed into 60Hz high – quality frequency – stabilized power supply, to supply power to ship electrical equipment.
2. Model Specification
Model: JDFSP – LH1 – 0.4/10 – 1250
- Rated capacity (KVA): As per model
- Rated voltage (KV): One Input One Output High Voltage In Low Voltage Out (specific values as in model naming)
- Product code: As per model naming
3. Technical Features
- Prefabrication: Electrical equipment integration, factory prefabrication, simple and convenient installation, effectively shortening the on – site installation and construction period.
- Convenient: Flexible lifting or truck transportation to the required location for power supply.
- Stable: Small harmonic components, instantaneous high – current surge without current – three – phase unbalanced voltage control, effective control of reverse power phenomenon.
- Protection: Phase loss protection, overvoltage and undervoltage protection; Short – circuit, overcurrent, overload protection; Lightning protection, overheating, grounding fault, communication fault, shore power interlock protection, etc.
- Control: IGBT power module, PID feedback control, output closed – loop control.
- IP Class: IP56
4. Technical Parameters
Outline
Two schemes are presented: Typical One Input Two Input High Voltage In Low Voltage Out Scheme and Typical One Input One Input High Voltage In Low Voltage Out Scheme, with block diagrams showing the components including Input Switchboard, Rectifier unit, Inversion unit, Filter unit, Power switching cabinet, Fry – type transformer, Output Switchboard, and Isolation transformer (in relevant scheme).
Main Technical Parameters
| Model | Rated capacity | Rated input voltage | Voltage fluctuation range | Input current harmonics | Rated output voltage | Output frequency | Output current harmonics | Environment – Temperature | Environment – Humidity | Environment – Altitude | IP Class |
|---|---|---|---|---|---|---|---|---|---|---|---|
| JDFSP – LH Series 400kVA – 5000kVA JDFSP – HL Series 400kVA – 5000kVA |
0.38kV/50Hz or 10kV/50Hz | -10% ~ +10% | ≤4% | 6.6kV/60Hz or 0.44kV + 6.6kV/60Hz (for LH series); 6.6kV/60Hz or 0.44kV + 6.6kV/60Hz (for HL series) | 50 ~ 60Hz | ≤2% | -10°C ~ +45°C, Rated usage can be reduced above 45°C | 5% – 95%, No condensation | ≤1500m, Over 1500m can be used with reduced rating | IP56 |
Notes: If you have special requirements, we can customize production according to the actual project.
Attention please: The description may be different with the goods, please contact us for confirmation.
Tag: Our other products