Cylinder Gauge

Delivery Time:10 Days
Packing Details:Carton
Place of Origin:China

Category:

Cylinder Liner Gauge Measurement Procedure

1. Zero Calibration

  • Step 1: Insert the zero-setting tool to depress the bore gauge thimble
  • Step 2: Rotate the dial until the main needle aligns with “0”
  • Verification: Confirm zero point is accurately set before measurement

2. Height Adjustment

  • Optimal Position: Set measurement point 5mm below piston ring edge
  • Adjustment Method: Turn the nut on the screw eye to fine-tune probe height

3. Measurement Process

  • Preparation:
    • Thoroughly clean cylinder liner surface
    • Clear scavenge ports of debris
  • Positioning:
    • Place measuring tool according to guide marks
    • Ensure bore gauge remains perpendicular to liner surface
  • Reading: Record measurements at both front and rear reference points

4. Safety Protocol

Prior to measurement, implement LOCKOUT/TAGOUT:

  1. System Shutdown:
    • Disable start mechanism
    • Secure starting air valve CLOSED
  2. Fluid Isolation:
    • Shut off fuel supply
    • Drain lubricating oil system
  3. Mechanical Safeguards:
    • Engage gear turning device OFF
    • Block cooling water circulation
    • Lock turbocharger rotor

The description/sizes may be different with goods, please check with us when order.