Marine DIN Standard Storm Valve

Place of Origin: Made In China
Specification: Please contact us for details.

Click here to send inquiry via whatsapp

Category:

Marine DIN Standard Storm Valve

Standards:

  • End Std.: EN 1092/A(DIN 2501).
  • Flanges drilled: PN10(DN50-DN250).
  • Face to Face Std.: DIN HN 50 Sr.6.
  • Pressure rating: PN4(DN50-DN250).
  • Manufactured in accordance to JIS F 7400.
  • Flanges as per JIS B 2220 – 5K, 10K.

Main Features:

No. Part Name Material
1 Body Nodular Cast iron
2 Bonnet Nodular Cast iron
3 Disc with Sealing Bronze+NBR
4 Bonnet Gasket NBR
5 Stem Brass
6 Stem Nut Brass
7 Handwheel Cast iron
8 Plug Brass
9 Stud Bolts Steel
10 Nut Steel
DN n1×∅d1 Hcd1 ∅D1 n2×∅d2 Hcd2 ∅D2 ∅D L1 H1 H2 ∅R Kg
50 4×18 125 165 8×18 160 200 70 180 90 260 140 12
65 4×18 145 185 8×18 180 220 85 200 100 270 140 14
80 8×18 160 200 8×18 210 250 100 215 108 290 140 20
100 8×18 180 220 8×22 240 285 130 250 130 305 140 25
125 8×18 210 250 8×22 270 315 158 290 152 330 160 36
150 8×22 240 285 8×22 295 340 190 330 176 360 160 43
200 8×22 295 340 12×22 350 395 240 425 180 350 160 72

Description:

Storm valve is a flap type non-return valve which is used to discharge the sewage overboard. It is connected to the soil pipe at one end and other end is at ships side so that sewage gets overboard. So it can be overhauled only during drydocks.

Inside the valve flap is there which is attached to a counter weight, and a locking block. The locking block is the piece of the valve that is controlled and operated by the external hand wheel or actuator. The purpose of the locking block is to hold the flap in place which ultimately prevents the flow of fluid.

Once flow begins, the operator must choose whether to open the locking block, or keep it closed. If the locking block is closed, the fluid will stay out of the valve. If the locking block is opened by the operator, fluid can flow freely through the flap. The pressure of the fluid will release the flap, allowing it to travel through the outlet in one direction. When flow stops, the flap will automatically return to its closed position.

Regardless of whether or not the locking block is in place, if flow comes through the outlet, the back flow will not be able to enter the valve due to the counterweight. This feature is identical to that of a check valve where back flow is prevented so that it will not contaminate the system. When the handle is lowered, the locking block will again secure the flap in its close position. The secured flap isolates the pipe for maintenance if necessary.

Applications:

Temperature Range: -10°C to +60°C.

Attention please: The description might be incorrect, please contact us for confirmation.